原子荧光光度法测定工业废水中的砷和硒 |
| |
引用本文: | 齐建,冯芸.原子荧光光度法测定工业废水中的砷和硒[J].江西化工,2013(4):147-149. |
| |
作者姓名: | 齐建 冯芸 |
| |
作者单位: | 周口市质量技术监督检验测试中心,河南周口466000 |
| |
摘 要: | 本文采用原子荧光光谱法,研究测定水样中砷和硒的技术.结果表明:用10%盐酸和1%硫脲-1%抗坏血酸混合试剂处理样品,并以1.0%硼氢化钾和0.5%氢氧化钠为还原剂,在5%的盐酸介质测定砷和硒.砷和硒的检出限分别为:0.20μg/L和0.13μg/L,本方法具有操作简便、快速、基体干扰少、灵敏度高等优点,可用于工业废水样中砷和硒的联合测定.
|
关 键 词: | 原子荧光光谱法 水 联合测定 砷和硒 |
Determination Of Trace As and Se In the Industrial Wastewater by AFS - 930 Atomic Fluorescence Spectrometer |
| |
Affiliation: | QI Jian FENG Yah ( Department of Zhoukou Administration of Quality, Supervision, Inspectionttenan Zhoukou 466000) |
| |
Abstract: | In this paper, the method on the AFS - 930 atomic fluorescence Spectrome - ter for determination of trace arsenic (As) and selenium (Se) in water was studied. The water sample was treated by 10 %HCL and 10 % Thiourea - 10 Ascorbicacid. The method is based on the reaction of arsenic (As) and selenium (Se) with KBH4 to form the hydride gas in medium of 5 % HCl. The detection limits are: As 0.20 μg/L Se: 0.13 μg/L. The method is simple, rapid, less, matrix interference and high sensitivity It can be applied to simultaneous determination of As and Se in the industrial wastewater. |
| |
Keywords: | Fluorescence spectrometric Industrial wastewater Simultaneous determination As and Se |
本文献已被 维普 等数据库收录! |
|