首页 | 本学科首页   官方微博 | 高级检索  
     

运用折流杆技术改造电站换热器的试验研究
引用本文:胡勇,吕圣杰.运用折流杆技术改造电站换热器的试验研究[J].广东电力,2005,18(5):51-53.
作者姓名:胡勇  吕圣杰
作者单位:广东省电力试验研究所,广东,广州,510600;茂港电力设备厂,广东,茂名,525000
摘    要:俄制300MW发电机组折流板结构闭冷器换热管在运行中短期内出现断裂泄漏,通过对泄漏原因的分析和研究,决定采用新型折流杆技术对换热器进行改造。试验表明折流杆换热器具有传热性能好、防振性能强、不易结垢和管程流动阻力小等优点,是高效、节能和耐用的新型换热器设备。

关 键 词:折流杆  折流板  换热器  振动  节能  换热效率
文章编号:1007-290X(2005)05-0051-03
修稿时间:2004年10月18

Test and research of improving power plant heat exchangers with baffle pole technique
HU Yong,Lü Sheng-jie.Test and research of improving power plant heat exchangers with baffle pole technique[J].Guangdong Electric Power,2005,18(5):51-53.
Authors:HU Yong  Lü Sheng-jie
Abstract:Breakage and leakage took place on the baffle plate heat exchangers of Russian-made 300 MW electric generator units in a power plant shortly after the units were put into operation. Upon analysis and research of the leakage causes, a new baffle pole technique was adopted to improve the heat exchangers. Test results show that the baffle pole heat exchanger is effective, energy saving and durable heat exchange equipment featured by good heat transfer and anti-vibration property, insusceptibility to scaling and small flow drag, etc.
Keywords:baffle pole  baffle plate  heat exchanger  vibration  energy saving  heat-exchanger efficiency  