首页 | 本学科首页   官方微博 | 高级检索  
     

铑自给能中子探测器的灵敏度
引用本文:杨有琏.铑自给能中子探测器的灵敏度[J].核电子学与探测技术,1989,9(3):135-141.
作者姓名:杨有琏
作者单位:北京核仪器厂
摘    要:本文给出了铑自给能探测器的热中子灵敏度和中子灵敏度的理论计算公式、燃耗修正公式以及不同中子温度下的换算公式。运用这些公式对ZTRh 123型铑自给能探测器的热中子灵敏度和中子灵敏度进行了理论计算,并在反应堆中对其进行了实验验证。其结果表明,理论计算值和实验标定值是相吻合的。其偏差:热中子灵敏度为8.5%,中子灵敏度为3.9%。

关 键 词:自给能  中子探测器  灵敏度  

Sensitivities of Rhodium Self-powered Neutron Detector
Yang Youlian.Sensitivities of Rhodium Self-powered Neutron Detector[J].Nuclear Electronics & Detection Technology,1989,9(3):135-141.
Authors:Yang Youlian
Affiliation:Beijing Nuclear Instrument Factory
Abstract:In this paper the theoretical calculation formulas for thermal neutron sensitivity and neutron sensitivity, the burn-up correction equations, and reduction formulas at different neutron temperature of rhodium self-powered in-core neutron detector are given. These formulas have been used in theoretical calculation for thermal neutron sensitivity and neutron sensitivity of type ZTRh123 rhodium self-powered detector, and experimentally verified in reactor. The results have indicated that the theoretical velues agreed with the experimental values: the deviation is 8.5% for thermal neutron sensitivity and 3.9% for neutron sensitivity.
Keywords:Self-powered  Neutron detector  Sensitivity
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号