摘    要:为研究脱硫废水烟道蒸发工艺对烟气酸露点的影响,在某600 MW机组上进行烟道蒸发中间试验(中试),实测废水蒸发前后烟气中H_2O和SO_3浓度,并采用不同计算公式计算酸露点。中试结果表明:在空气预热器后1/4烟道中(烟气量为4×10~5~5×10~5 m^3/h)喷入900~1 400 L/h的废水时,烟气中的水蒸气质量分数增加了0.7~0.9个百分点,而烟气中的SO_3浓度却降低30%~50%,说明废水烟道蒸发促进了SO_3向硫酸雾的转化并促进了其在飞灰颗粒上的吸附;废水喷入烟道蒸发后,烟气酸露点反而有所降低,虽然烟气平均温度降低了9~14℃,但废水喷入后的烟温仍基本高于废水喷入后的酸露点,因而脱硫废水烟道蒸发不会造成下游烟道和设备的低温腐蚀。

关 键 词:燃煤机组  脱硫废水  烟道蒸发  酸露点  SO3
收稿时间:2018-04-02
修稿时间:2018-06-16

Analysis on the Influence of the Wastewater Evaporation in Flue Duct to the Flue Gas Dew Point
WU Zhiquan,CAO Fan,YUAN Yuan,JIA Xibu.Analysis on the Influence of the Wastewater Evaporation in Flue Duct to the Flue Gas Dew Point[J].Electric Power,2019,52(1):151-155,184.
Authors:WU Zhiquan  CAO Fan  YUAN Yuan  JIA Xibu
Affiliation:China Datang Corporation Science and Technological Research Institute, Beijing 100043, China
Abstract:The effect of the wastewater evaporation in flue duct to the flue gas dew point was studied in this article. Pilot test of the wastewater evaporation was conducted on a 600 MW unit. The H2O and SO3 contents in the flue gas were detected and the dew point was calculated using different formulas. The results showed that, when 900~1 400 L/h wastewater was injected in 1/4 flue duct of the 600 MW unit (the amount of flue gas was 4×105~5×105 m3/h), the water vapor in the flue gas increased 0.7%~0.9%, whereas the SO3 decreased by 30%~50%, which indicated that the transformation from SO3 to sulfuric acid mist and their adsorption on fly ash particles were improved after the wastewater evaporation. The flue gas dew point decreased by 9~14 ℃ after the evaporation, and the flue gas temperature could be higher than the dew point. Thus, wastewater evaporation in flue duct could not lead to low-temperature corrosion of the downstream ducts and equipments under the condition of pilot test.
Keywords:coal-fired unit  desulfurization wastewater  flue duct evaporation  acid dew point  SO3  
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《中国电力》浏览原始摘要信息
点击此处可从《中国电力》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号