摘    要:为了探究达到设计寿命的高压交联电缆继续运行的可靠性,文中对一回实际运行32 a的110 kV高压交联聚乙烯(XLPE)电缆采用预鉴定试验方法,进行为期180 d的电热循环加速老化试验。通过综合分析比较试验过程中电缆绝缘内、中和外层的电场强度和温度场变化的差异,并将各绝缘层试验条件转化为导体芯表面得到相应的等效试验条件,发现电缆绝缘中层和外层的等效试验条件接近电缆的实际运行情况。通过相关理化实验分析比较试验前后电缆绝缘各层的微观和聚集态状况。结果发现:绝缘内层在严苛的试验条件下热氧化降解占主导;绝缘中层虽然发生一定的氧化降解,但晶体结构仍有所改善;绝缘外层的结晶形态在温度效应的热刺激下趋于完善。因此,可以评估该退役电缆的其余部分在实际运行条件下仍具有长期服役的潜能。

关 键 词:电缆  交联聚乙烯  加速老化  FTIR  DSC  TG  XRD
收稿时间:2020/5/11 0:00:00
修稿时间:2020/7/13 0:00:00

Effect of electro-thermal aging on characteristics of XLPE cable insulation
Authors:WANG Yanfeng  YAN Guobing  XIE Rongchang  SUN Qiang  ZHU Wenwei  ZHAO Yifeng  LIU Gang
Affiliation:Guangdong Power Grid Co Ltd Grid Planning Research Center,Guangdong Power Grid Co, Ltd,Guangdong Power Grid Co, Ltd,Guangdong Power Grid Co, Ltd,Guangdong Power Grid Co Ltd Grid Planning Research Center,South China University of Technology,South China University of Technology
Abstract:In order to investigate the reliability of the continuous operation of the high voltage cross-linked cable which has reached the design life limit. a 180-day pre-qualification test method was carried out on a section of high-voltage cross-linked cable which has been in operation for 32 years. This paper analyzes the electric field strength and temperature variation in the inner, medium and outer layers of the cable insulation during the test, and converted to the corresponding equivalent condition at the surface of the conductor core. It can be found that equivalent testing conditions of the medium and outer positions are close to the cable practical operation condition. Several diagnostic measurements were conducted to analyze the micro-structure and aggregation structure among the samples. The results showed that the inner layer produced more small molecular chains and oxygen-containing groups in the high-strength test condition; the medium layer insulation had a certain oxida-tive degradation, but the crystalline structure was still improved after the moderate condition; the crystalline form of the outer layer insulation have been improved under the equivalent testing condition. Therefore, it can be expected that the rest of this retired cables still have the potential to reuse in long-term actual operation condi-tion.
Keywords:cable  cross-linked polyethylene  accelerated aging  FTIR  DSC  TG  XRD