首页 | 本学科首页   官方微博 | 高级检索  
     

20000m~3/h空分设备氩馏分组分异常的分析和处理
引用本文:牛建军.20000m~3/h空分设备氩馏分组分异常的分析和处理[J].深冷技术,2014(4):63-66.
作者姓名:牛建军
作者单位:河北钢铁集团舞阳钢铁有限责任公司,河南省舞钢市湖滨大道西段462500
摘    要:舞钢20000 m3/h空分设备在建成投产后出现氩馏分组分异常现象,在各项工艺调整措施无效后,进行上塔吊出检查并实施改进处理,使氩馏分组分恢复正常。介绍上塔拆除检查和处理方案,分析上塔的杂质堵塞、填料及分布器安装等影响因素。

关 键 词:空分设备  制氩系统  氩馏分  上塔  规整填料塔  拆除  检修

Analysis and treatment of abnormal compositions of argon fraction of 20000 m3/h air separation plant
Niu Jianjun.Analysis and treatment of abnormal compositions of argon fraction of 20000 m3/h air separation plant[J].Cryogenic Technology,2014(4):63-66.
Authors:Niu Jianjun
Affiliation:Niu Jianjun ( Hebei Iron & Steel Group Wuyang Iron & Steel Co. , Ltd. , Western section, Hubin Road, Wugang 462500, Henan, P. R. China)
Abstract:After putting into operation of 20000 m3/h air separation plant of Wuyang Iron & Steel, abnormal composition of argon fraction occurred. After process adjustment measures failed, the upper tower was lifted out, checked, and corrected to restore the normal composition of argon fraction. The removal, check and correction scheme of the upper tower are briefed, and the affecting factors such as impurity blocking, packing, and distributor installation are analyzed.
Keywords:Air separation plant  Argon-making system  Argon fraction  Upper tower  Regular packed tower  Removal  Repair