420t/h煤粉炉超温分析及改进 |
| |
引用本文: | 杨洪亮,葛翔,石斌,杜斌.420t/h煤粉炉超温分析及改进[J].能源工程,2012(2):66-69. |
| |
作者姓名: | 杨洪亮 葛翔 石斌 杜斌 |
| |
作者单位: | 1. 湖州市特种设备检测中心,浙江湖州,313000 2. 浙江省特种设备检验研究院,浙江杭州,310015 3. 嘉兴市特种设备检测院,浙江嘉兴,314000 |
| |
摘 要: | 对某火电厂420 t/h煤粉炉的主蒸汽温度偏差、对流过热器左右侧烟温偏差、对流受热面右侧严重磨损等情况进行了详细的分析和探讨,提出了改进方案,并对改进效果进行了对比。
|
关 键 词: | 煤粉炉 超温 改进 |
Analysis and improvement of overheating in 420 t/h pulverized coal fired boiler |
| |
Affiliation: | YANG Hong-liang1,GE Xiang2,SHI Bin3,et al(1.Huzhou Special Equipment Inspection Center,Huzhou 313000,China;2.Zhejiang Special Equipment Inspection and Research Institute,Hangzhou 310015,China; 3.Jiaxing Special Equipment Inspection Institute,Jiaxing 314000,China) |
| |
Abstract: | Analysis and discussion on main steam temperature deviation,different sides of convection superheater gas temperature deviation,severe wear of right side of convection heating surface were conducted in 420 t/h pulverized coal fired boiler in power plant,an improvement scheme was proposed,and the effect of the change was contrasted. |
| |
Keywords: | pulverized coal fired boiler overheating improvement |
本文献已被 CNKI 维普 万方数据 等数据库收录! |
|