首页 | 本学科首页   官方微博 | 高级检索  
     

Determination of Trace Metal Impurities in Cerium Oxide by Fluorination-Assisted ETV-ICP-AES after HPLC Separation
作者姓名:Ruth Wanjau  胡斌  江祖成  秦永超  何蔓  梁沛
作者单位:DepartmentofChemistry,WuhanUniversity,Wuhan430072,China)
基金项目:国家自然科学基金,Wuhan Municipal Science & Technology Commission
摘    要:A new method for the separation and detection of trace metal impurities in cerium oxide (CeO2) using HPLC combined with electrothermal vaporization (ETV)-ICP-AES was developed. This combination links the high separation power of HPLC and high sensitivity of ETV-ICP-AES. The 2-ethylhexyl hydrogen 2-ethylhexylphosphate (P507) resin was used as stationary phase for the separation of metallic impurities in order to eliminate severe spectral interferences of the matrix. The dilute nitric acid was adopted as mobile phase for eluting Cu, Mn, Ni and La. The separation process can be accomplished in about 30 min. After concentrating the eluate by evaporation, the trace impurities were determined by using ETV-ICP-AES with the addition of 6% PTFE slurry as chemical modifier. The proposed method was applied to the analysis of CeO2 with satisfactory recoveries.

关 键 词:二氧化铈  测定  ETV-ICP-AES  HPLC  稀土  光度法

Determination of Trace Metal Impurities in Cerium Oxide by Fluorination-Assisted ETV-ICP-AES after HPLC Separation
Ruth Wanjau.Determination of Trace Metal Impurities in Cerium Oxide by Fluorination-Assisted ETV-ICP-AES after HPLC Separation[J].Journal of Rare Earths,2004,22(2):197-200.
Authors:Ruth Wanjau
Abstract:A new method for the separation and detection of trace metal impurities in cerium oxide(CeO2)using HPLC combined with electrothermal vaporization(ETV)-ICP-AES was developed.This combination links the high separation power of HPLC and high sensitivity of ETV-ICP-AES.The 2-ethylhexyl hydrogen 2-ethylhexylphosphate(P507)resin was used as stationary phase for the separation of metallic impurities in order to eliminate severe spectral interferences of the matrix.The dilute nitric acid was adopted as mobile phase for eluting Cu,Mn,Ni and La.The separation process can be accomplished in about 30 min.After concentrating the eluate by evaporation,the trace impurities were determined by using ETV-ICP-AES with the addition of 6% PTFE slurry as chemical modifier.The proposed method was applied to the analysis of CeO2 with satisfactory recoveries.
Keywords:chemical analysis  fluorination-electrothermal vaporization  HPLC  P507 resin  cerium oxide  rare earths
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号