首页 | 本学科首页   官方微博 | 高级检索  
     


Application of microfiltration systems coupled with powdered activated carbon to river water treatment
Affiliation:1. Division of Environmental Engineering and Biotechnology, Myongji University, San 38-2, Namdong, Yongin, Kyonggido 449-728, South Korea;2. Department of Urban Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan;1. State Key Laboratory of Urban Water Resource and Environment (SKLUWRE), Harbin Institute of Technology, No. 73 Huanghe Road, Nangang District, Harbin 150090, China;2. Jinan Water and Wastewater Monitoring Center, No. 68 Weiwu Road, Shizhong District, Jinan 250021, China;1. Department of Food Science and Human Nutrition, Agricultural University of Athens, Iera Odos 75, Athens 11855, Greece;2. Avecom NV, Industrieweg 122P, 9032 Wondelgem, Belgium;1. State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin, 150090, China;2. Nanyang Environment and Water Research Institute (NEWRI), Nanyang Technological University, 1 Cleantech Loop, Singapore, 637141, Singapore
Abstract:A bench scale submerged microfiltration system coupled with high concentration of PAC (powdered activated carbon) was applied in order to purify a river water containing secondary effluent. The system was operated with four different modes: Run-1, -2, -3 and -4. The PAC concentration was set at 0, 4 and 40 g/L with same filtration rate of 1.0 m/d (42 L/m2/h) which correspond to Run-1, -2 and -3. In Run-4, the filtration rate was set at 0.5 m/d (21 L/m2/h) with PAC concentration of 40 g/L. The effluent turbidity showed below 0.1 NTU for all runs, and the removal rates more than 90% were observed. As for TOC removal, almost no removal of TOC was observed in Run-1 while the higher removal rates were obtained with the higher dosage of powdered activated carbon. Run-3 and 4 with PAC dose of 40 g/L showed the removal of 85% regardless of the filtration rates. Removal of UV254 was similar to that of TOC: removal of 13% at Run-1 and 90% at Run-3 and -4. As for the filtration efficiency, an average filtration time for TMP to reach 60 kPa was checked for each runs. The filtration time of around 5 days was observed in Run-1 and Run-2, 2 days in Run-3 and 60 days in Run-4. According to the results, the effluent water quality got better with higher dose of PAC and the filtration efficiency was enhanced with higher dose of PAC and lower filtration time.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号