首页 | 本学科首页   官方微博 | 高级检索  
     

循环流化床锅炉炉管磨损原因分析与治理
引用本文:李正平.循环流化床锅炉炉管磨损原因分析与治理[J].陕西电力,2007,35(4):75-78.
作者姓名:李正平
作者单位:神华集团神东电力公司自备电厂,陕西,榆林,719316
摘    要:分析了神华集团神东电力公司自备电厂循环流化床锅炉水冷壁存在的磨损现象,通过采取调整运行、改进结构、调整物料流量、强化水冷壁表面等措施,使水冷壁管磨损现象得到了有效控制。

关 键 词:CFB锅炉  磨损  治理
文章编号:1673-7598(2007)04-0075-04
收稿时间:2007-02-10
修稿时间:2007年2月10日

Discussion on Causes and Control Strategies for Boiler Tube Abrasion of Circulating Fluidized Bed Boiler
LI Zheng-ping.Discussion on Causes and Control Strategies for Boiler Tube Abrasion of Circulating Fluidized Bed Boiler[J].Shanxi Electric Power,2007,35(4):75-78.
Authors:LI Zheng-ping
Abstract:The abrasion problem of water wall in CFB boiler in Shenmu Group Shendong Electric Power Company Self-contained Power Plant is analyzed, then remedial measures, such as adjusting operation, modifying structure, regulating charges flow and treating surface, have been taken to control abrasion of water wall.
Keywords:CFB boiler  abrasion  control strategy
本文献已被 维普 万方数据 等数据库收录!