On the selection of fin profiles for OTEC plate-fin evaporators |
| |
Authors: | V. R. Raghavan M. S. Murthy |
| |
Affiliation: | Department of Mechanical Engineering, Indian Institute of Technology, Madras 600 036, India |
| |
Abstract: | ![]() This paper considers the plate-fin heat exchanger for an OTEC power plant on account of its compactness. Ammonia is selected as the working fluid for a plant of 1 MW gross output. Choice of seawater side velocity is made on the basis of pressure drop and biofouling. Fourteen different fin profiles are considered in order to choose a suitable configuration. The selection of the plate-fin heat exchanger depends on minimum exchanger volume, minimum pumping power requirement and low ammonia side pressure drop. |
| |
Keywords: | OTEC Ammonia Evaporator Plate-fin Volume Pumping power |
本文献已被 ScienceDirect 等数据库收录! |