Abstract:Abstract

Cathodic protection (CP) monitoring in the presence of simultaneous AC and DC interference could lead to erroneous measurements, since IR drop contribution due to both DC and AC could heavily affect potential readings. Therefore, to know the true potential (or true polarisation level), the ohmic drop contribution has to be eliminated. In literature, there is lack of agreement about the proper procedure to measure the true potential in the presence of AC. Laboratory tests on carbon steel specimens in soil simulating conditions were carried out focusing on potential measurement problem in the presence of AC through standard potential measurement procedure and the use of a potential probe. Results suggest the need of a proper methodology for potential measurement to determine reliably CP conditions.
Keywords:AC interference  Ohmic drop  Potential probe  Cathodic protection  Monitoring