首页 | 本学科首页   官方微博 | 高级检索  
     


Development and Integration of a Data Acquisition System for SST-1 Phase-1 Plasma Diagnostics
Authors:Amit K Srivastava  Manika Sharma  Imran Mansuri  Atish Sharma  Tushar Raval  Subrata Pradhan
Affiliation:Amit K SRIVASTAVA,Manika SHARMA,Imran MANSURI,Atish SHARMA,Tushar RAVAL,Subrata PRADHAN SST-1 Group,Institute for Plasma Research,Gandhinagar-382 428,India
Abstract:Long pulse (of the order of 1000s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physics information) while avoiding unnecessary generation of a large volume data. SST-1 Phase-1 tokamak operation has been envisaged with data acquisition of several essential diagnostics channels. These channels demand data acquisition at a sampling rate ranging from 1KSPS to 1MSPS. Considering the technical characteristics and requirements of the diagnostics, a data acquisition system based on PXI and CAMAC has been developed for SST-1 plasma diagnostics. Both these data acquisition systems are scalable. Present data acquisition needs involving slow plasma diagnostics are catered by the PXI based data acquisition system. On the other hand, CAMAC data acquisition hardware meets all requirements of the SST-1 Phase-1 fast plasma diagnostics channels. A graphical user interface for both data acquisition systems (PXI and CAMAC) has been developed using LabVIEW application development software. The collected data on the local hard disk is directly streaming to the central server through a dedicated network for post-shot data analysis. This paper describes the development and integration of the data acquisition system for SST-1 Phase-1 Plasma Diagnostics. The integrated testing of the developed data acquisition system has been performed using SST-1 Central control and Diagnostics Signal Conditioning units. In the absence of plasma shots, the integrated testing of the data acquisition system for the initial diagnostics of SST-1 Phase-1 operation has been performed with simulated physical signals. The primary engineering objective of this integrated testing is to validate the performance of the developed data acquisition system under simulated conditions close to that of actual tokamak operation. The data acquisition is synchronized with a clock and trigger provided by the central timing system.
Keywords:SST-1  data acquisition  CAMAC  PXI  plasma diagnostics  
本文献已被 CNKI 等数据库收录!
点击此处可从《等离子体科学和技术》浏览原始摘要信息
点击此处可从《等离子体科学和技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号