首页 | 本学科首页   官方微博 | 高级检索  
     

基于深度神经网络伪量测建模的交直流混合配电网交替迭代法状态估计
引用本文:龚逊东,费有蝶,凌佳凯,胡金峰,秦军,卫志农,臧海祥.基于深度神经网络伪量测建模的交直流混合配电网交替迭代法状态估计[J].电力建设,2022,43(10):111-120.
作者姓名:龚逊东  费有蝶  凌佳凯  胡金峰  秦军  卫志农  臧海祥
作者单位:1.国网江苏省电力有限公司无锡供电分公司,江苏省无锡市 2140612.河海大学能源与电气学院,南京市 211100
基金项目:国网江苏省电力有限公司科技项目(J2021026);国家自然科学基金资助项目(U1966205)
摘    要:当前配电网状态估计面临的一个突出问题是实时量测数量不足,难以实现全网可观性。为了给配电管理系统提供准确的基础数据,提出一种基于深度神经网络伪量测建模的交直流混合配电网交替迭代状态估计方法。首先,建立电压源换流器的稳态模型和混合配电网的实时量测模型;然后,利用历史量测数据对深度神经网络进行离线训练,建立负荷节点注入功率的伪量测模型;最后,对交流区域和直流区域进行交替迭代状态估计,在交替过程中区域间交换VSC支路状态量的估计值,保证了边界状态量的一致性。算例测试结果表明,所提方法能在实时量测覆盖率低的情况下,准确估计混合配电网的状态值。

关 键 词:混合配电网  交替迭代状态估计  深度神经网络  伪量测  
收稿时间:2022-03-23

Alternating-Iteration State Estimation of AC/DC Hybrid Distribution System Based on Pseudo-Measurement Modeling Using Deep Neural Network
GONG Xundong,FEI Youdie,LING Jiakai,HU Jinfeng,QIN Jun,WEI Zhinong,ZANG Haixiang.Alternating-Iteration State Estimation of AC/DC Hybrid Distribution System Based on Pseudo-Measurement Modeling Using Deep Neural Network[J].Electric Power Construction,2022,43(10):111-120.
Authors:GONG Xundong  FEI Youdie  LING Jiakai  HU Jinfeng  QIN Jun  WEI Zhinong  ZANG Haixiang
Affiliation:1. Wuxi Power Supply Company of State Grid Jiangsu Electric Power Co., Ltd., Wuxi 214061, Jiangsu Province, China2. College of Energy and Electrical Engineering, Hohai University, Nanjing 211100, China
Abstract:At present, a prominent problem in the state estimation of distribution system is the lack of real-time measurements, which makes it difficult to realize the observability of the whole network. In order to provide accurate basic data for distribution management system (DMS), an alternating-iteration state estimation method based on pseudo measurement modeling using deep neural networks (DNN) is proposed. Firstly, the steady-state model of voltage source converter (VSC) and the real-time measurement model of hybrid distribution system are presented. Then the historical measurements are used to train DNN off-line and establish pseudo-measurement models of power injection on load buses. Finally, alternating-iteration state estimation is carried out for AC and DC areas. Only the estimated states of VSC branches need to be exchanged, thus ensuring the consistency of the boundary states. Test results show that the proposed method can accurately estimate the states of hybrid distribution system under low coverage of real-time measurements.
Keywords:hybrid distribution system  alternating-iteration state estimation  deep neural network  pseudo measurement  
点击此处可从《电力建设》浏览原始摘要信息
点击此处可从《电力建设》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号