首页 | 本学科首页   官方微博 | 高级检索  
     


A new method of two-phase flow measurement by orifice plate differential pressure noise
Authors:Wang Wenran  Tong Yunxian
Affiliation:

Institute of Nuclear Energy Technology, Tsinghua University, Beijing 100084, People's Republic of China

Abstract:The mechanism of differential pressure noise of orifices in two-phase flow has been investigated and a theoretical model has been developed for measurement of the double parameters, i.e. mass flow rate as well as phase fraction (steam quality). The model has been proved in a set of orifice experiments in a two-phase flow system at a pressure range of 5.8–12.1 MPa and steam quality of 0.05–0.95, and a practical model has been fitted. The r.m.s. errors of mass flow rate and steam quality estimated by the model are 9.0 and 6.5%, respectively. The results of the studies create a method to measure double parameters of two-phase flow at once using only a single orifice.
Keywords:orifice noise   two-phase flow   flow rate measurement   phase fraction
本文献已被 ScienceDirect 等数据库收录!