首页 | 本学科首页   官方微博 | 高级检索  
     


Performance characteristics of a small-capacity directly cooled refrigerator using R290/R600a (55/45)
Authors:Moo-Yeon Lee   Dong-Yeon Lee  Yongchan Kim  
Affiliation:aDepartment of Mechanical Engineering, Korea University, Anam-Dong, Sungbuk-Gu, Seoul 136-713, Republic of Korea;bDepartment of Mechanical Engineering, KAIST, Daejeon, Republic of Korea
Abstract:In this study, the performance of a small-capacity directly cooled refrigerator was evaluated by using the mixture of R290 and R600a with mass fraction of 55:45 as an alternative to R134a. The compressor displacement volume of the alternative system with R290/R600a (55/45) was modified from that of the original system with R134a to match the refrigeration capacity. Both systems with R290/R600a (55/45) and R134a were tested, and then optimized by varying the refrigerant charge and capillary tube length under experimental conditions for both the pull-down test and the power consumption test. The refrigerant charge of the optimized R290/R600a system was approximately 50% of that of the optimized R134a system. The capillary tube lengths for each evaporator in the optimized R290/R600a system were 500 mm longer than those in the optimized R134a system. The power consumption of the optimized R134a system was 12.3% higher than that of the optimized R290/R600a system. The cooling speed of the optimized R290/R600a (55/45) system at the in-case setting temperature of −15 °C was improved by 28.8% over that of the optimized R134a system.
Keywords:Domestic refrigerator   Binary mixture   Propane   Isobutane   Experiment   Comparison   R134a   PerformanceMots clé  s:   frigé  rateur domestique    lange binaire   Propane   Isobutane   Expé  rimentation   Comparaison   R134a   Performance
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号