首页 | 本学科首页   官方微博 | 高级检索  
     

中波发射台周围地面场强计算结果与实测值比较分析
引用本文:陈琼霞.中波发射台周围地面场强计算结果与实测值比较分析[J].辐射防护通讯,2016,36(2):36-38.
作者姓名:陈琼霞
作者单位:福建省辐射环境监督站, 福州, 350012
摘    要:以某8塔共址的中波发射台为例,对多个不同发射功率的发射塔同时运行时地面电场强度进行40 V/m等值线标准方法的计算与实测。结果显示,仅2座发射功率≥50 kW发射塔周围可实测到40 V/m等值线,实测值与国家环境行业标准规定方法计算结果相差约30%。

关 键 词:中波发射台  地面电场强度  40  V/m等值线  
收稿时间:2016-01-16

A Comparative Analysis of the Calculated and the Measured Ground Electric Field Strength Values around a Medium-Wave Broadcasting Station
Chen Qiongxia.A Comparative Analysis of the Calculated and the Measured Ground Electric Field Strength Values around a Medium-Wave Broadcasting Station[J].Radiation Protection Bulletin,2016,36(2):36-38.
Authors:Chen Qiongxia
Affiliation:Fujian Radiation Environment Monitoring Center, Fuzhou, 350012
Abstract:The ground Electric field strength wastheoretically estimated and measured, with respect to the 40 V/m contour standard method, for several medium-wave transmitting towers with different radiationpower run at the same time, with an 8-tower collocated medium-wave broadcasting station taken as an example. It shows that only two towers with power greaterthan 50 kW can be measured to 40 V/m contour, and the difference between the values and the results estimated with the national environmental industry standardmethod is about 30%.
Keywords:Medium wave antenna  Ground electric field strength  40 V/m contour  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《辐射防护通讯》浏览原始摘要信息