Thermal performance of a flat-plate heat-pipe collector array |
| |
Authors: | T.Y. Bong K.C. Ng H. Bao |
| |
Affiliation: | Department of Mechanical and Production Engineering, National University of Singapore, Singapore 0511 |
| |
Abstract: | This article presents a theoretical model for the determination of the efficiency, the heat removal factor, and the outlet water temperature of a single collector and an array of flat-pipe heat-pipe collectors. The model is validated by on-site testing of 16 heat-pipe collectors under the typical weather conditions in Singapore. Within the operational range of interest of the hot water temperatures, the results show that the proposed model is sufficient to describe the steady-state performance of the collector array. |
| |
Keywords: | |
本文献已被 ScienceDirect 等数据库收录! |
|