建筑消火栓给水系统设计的几点探讨
引用本文:顾康平.建筑消火栓给水系统设计的几点探讨[J].山西建筑,2011,37(2):112-114.
作者姓名:顾康平
作者单位:杭州市铁路投资有限公司,浙江,杭州,310021
摘    要:结合实际工程,对建筑消火栓给水系统设计中消防给水方式、消防水箱水量、最不利点消火栓口静水压力的计算、消防水泵选择等进行了探讨,并提出了自己的建议,从而使消火栓给水系统设计满足规范要求。

关 键 词:消防给水方式  消防水箱  最不利点消火栓静水压力  消防水泵

Exploration on design of building fire hydrant water supply system
GU Kang-ping.Exploration on design of building fire hydrant water supply system[J].Shanxi Architecture,2011,37(2):112-114.
Authors:GU Kang-ping
Affiliation:GU Kang-ping
Abstract:Based on instance of engineering,this paper discusses the fire water supply means,volume of fire water tank,hydrant hydrostatic pressure at the most unfavorable point,and fire water pump selection and other aspects in the design of building fire hydrant water supply system,and proposes suggestions,so as to make the design of hydrant water supply system meet standardized requirements.
Keywords:hydrant water supply method  fire water tank  hydrant hydrostatic pressure at the most unfavorable point  fire water pump  