首页 | 本学科首页   官方微博 | 高级检索  
     


Geochemical characteristics of the Yufuin outflow plume, Beppu hydrothermal system, Japan
Authors:NC Sturchio  S Ohsawa  Y Sano  G Arehart  K Kitaoka  Y Yusa
Affiliation:?Argonne National Laboratory, Geoscience/CMT-205, Argonne, IL 60439, U.S.A.;?Beppu Geophysical Research Laboratory, Kyoto University, Beppu 874, Japan;?Department of Earth and Planetary Sciences, Hiroshima University, Higashi-Hiroshima 724, Japan
Abstract:Thermal water at Yufuin (Kyushu Island, Japan) is tapped through about 820 shallow wells and used mainly for hot-spring bathing purposes. Chemical and isotopic data for fluids from wells and fumaroles in Yufuin and Beppu indicate that the thermal activity at Yufuin represents a dilute, westward-flowing hydrothermal outflow plume from the Beppu hydrothermal system. Two other (eastward-flowing) outflow plumes have long been recognized at Beppu, but the Yufuin outflow plume is first recognized here. The Yufuin outflow plume is apparently a mixture of two end-member fluids: (1) deep high-temperature (250–300°C) fluid from the Beppu system having high chloride concentration (1400–1600 mg/L) and a δ18O value near −6.0%, and (2) meteoric water having low chloride concentration (≤7 mg/L) and a δ18O value near −9.2%.A permeable conduit for the vertical and lateral transport of deep fluid from the Beppu system is provided by the Yufuin Fault zone, which extends westward from the southern flank of Mt. Tsurumi volcano to the town of Yufuin. Stable isotope ratios and chloride concentrations for shallow groundwaters near the eastern end of the fault, at an elevation near 700 m, are consistent with those required for the low-chloride meteoric end-member of the Yufuin thermal waters. Recharge of this meteoric water, as well as mixing with the Beppu deep fluid, may occur along the Yufuin Fault. Enthalpy-chloride relations indicate additional conductive heating of the Yufuin waters, in the amount of 350–500 kJ/kg beyond that which can be accounted for by mixing between Beppu deep fluid and meteoric water. This could be a result of conductive heating with convection to a depth of 1–2 km. Estimates of the magnitude of the heat source for the Beppu hydrothermal system should take into account the heat being discharged at Yufuin.
Keywords:Beppu hydrothermal system  geochemistry  steam wells  thermal waters  stable isotopes  outflow plumes  Japan
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号