首页 | 本学科首页   官方微博 | 高级检索  
     

基于主成分分析马氏距离的支腿控制阀健康评估
引用本文:张旭东,黄亦翔,单增海.基于主成分分析马氏距离的支腿控制阀健康评估[J].振动与冲击,2020,39(3):46-51.
作者姓名:张旭东  黄亦翔  单增海
作者单位:1.上海交通大学机械系统与振动国家重点实验室, 上海200240;
2.徐州重型机械有限公司高端工程机械智能制造国家重点实验室, 江苏 徐州221004
摘    要:支腿控制阀的性能是影响起重机支腿系统伸缩性能的重要因素之一。为了准确的评估支腿控制阀的健康性能,提出一种支腿系统的性能衰退与健康状态的评估方法,该方法基于PCA降维与马氏距离相结合的分析模型,建立不同状态下传感器信号与关键零部件的映射关系,从而达到对起重机支腿系统性能衰退量化评估的目的。该方法应用于起重机支腿控制阀的压力信号,通过对传感器信号内蕴关系及起重机在各年份提取的特征在特征空间的相关性分析,以得到量化性能评估结果。与常见的其他方法相比,该模型能够准确地反映起重机支腿系统历年来的性能衰退趋势,具有更好的鲁棒性与泛化性。

关 键 词:支腿控制阀')"  href="#">  />  支腿控制阀    主成分分析    马氏距离    健康评估    性能衰退  

Health evaluation of a crane’s leg control valve based on PCA and Mahalanobis distance
ZHANG Xudong,HUANG Yixiang,SHAN Zenghai.Health evaluation of a crane’s leg control valve based on PCA and Mahalanobis distance[J].Journal of Vibration and Shock,2020,39(3):46-51.
Authors:ZHANG Xudong  HUANG Yixiang  SHAN Zenghai
Affiliation:1.State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, China; 2.Xuzhou Heavy Machinery Limited Company and State Key Laboratory of Advanced Manufacturing Machinery Intelligent Manufacturing, Xuzhou 221004, China
Abstract:The performance of a leg control valve is one of important factors affecting telescopic performance of a crane’s leg system.Here, in order to accurately evaluate health performance of a leg control valve, an evaluation method for crane leg system’s performance degradation and health state was proposed based on the analysis model using the principal component analysis (PCA) dimension reduction combined with Mahalanobis distance to establish a mapping relation between sensor signals and key components under different states, and achieve the goal to quantitatively evaluate a crane leg system’s performance degradation.The method was used with pressure signals of a crane’s leg control valve.Its quantitative performance evaluation results were obtained using the correlation analysis of sensor signal implication relation and crane’s each year features extracted in the feature space.It was shown that compared with other methods, the proposed model can accurately reflect performance degradation trend of a crane leg system over years with better robustness and generalization.
Keywords:outrigger control valves                                                      principal component analysis (PCA)                                                      Mahalanobis distance                                                      health evaluation                                                      performance degradation
本文献已被 CNKI 等数据库收录!
点击此处可从《振动与冲击》浏览原始摘要信息
点击此处可从《振动与冲击》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号