首页 | 本学科首页   官方微博 | 高级检索  
     

聚苯乙烯中残余苯乙烯测定方法的建立
引用本文:郑利红,蔡登定,米燕,高玲,谢力潘.聚苯乙烯中残余苯乙烯测定方法的建立[J].分析仪器,2017(4):62-67.
作者姓名:郑利红  蔡登定  米燕  高玲  谢力潘
作者单位:中国石油独山子石化公司,独山子,833699
摘    要:参照ISO 2561:2012,采用气相色谱法测定聚苯乙烯中的残余苯乙烯1],将聚合物样品溶于含有正丁基苯内标物的N,N-二甲基甲酰胺溶剂中,然后将少量聚合物溶液直接注入气相色谱中(方法 A);或将沉淀剂加入到聚合物溶液中,待沉淀后取上层清液注入到气相色谱中进行测定(方法 B)。测定结果的重复性满足方法重复性±5%的要求,两种方法的回收率都在100±5%范围内。

关 键 词:聚苯乙烯  气相色谱法

Establishment of a method for determining residual styrene contained in polystyrene
Zheng Lihong,Cai Dengding,Mi Yan,Gao Ling,Xie Lipan.Establishment of a method for determining residual styrene contained in polystyrene[J].Analytical Instrumentation,2017(4):62-67.
Authors:Zheng Lihong  Cai Dengding  Mi Yan  Gao Ling  Xie Lipan
Abstract:Residual styrene contained in polystyrene was determined in this paper with reference to ISO 2561:2012,using gas chromatography.The polymer samples were dissolved in N,N-dimethylformamide(DMF) solvent and n-butyl benzene was used as internal standard substance.A little polymer solution was directly injected into gas chromatograph(method A) or precipitant was added into polymer solution, and then supernatant after precipitation would be injected into gas chromatograph (method B).The test results of two methods showed that the repeatability errors were ±5% and recovery rates were 100±5%, they all can meet the test requirement.
Keywords:polystyrene  gas chromatograph
本文献已被 CNKI 维普 万方数据 等数据库收录!