首页 | 本学科首页   官方微博 | 高级检索  
     


An instrumentation system for multi-parameter measurements of gas-solid two-phase flow based on Capacitance-Electrostatic sensor
Affiliation:1. Dept. of Information Technology and Electrical Engineering, University of Naples “Federico II”, via Claudio 21, 80125 Naples, Italy;2. Dept. of Electrical and Information Engineering, University of Cassino and Southern Lazio, via G. Di Biasio, 43, 03043 Cassino, Italy;1. School of Physical Electronics, University of Electronics Science and Technology of China, Chengdu 610054, China;2. Institute of Applied Physics, A''ba Teachers College, Wenchuan, Sichuan 623000, China;1. School of Process, Environmental and Materials Engineering, Leeds LS2 9JT, United Kingdom;2. School of Earth and Environment, University of Leeds, Leeds LS2 9JT, United Kingdom
Abstract:In this paper, an instrumentation system for the measurements of local solid volumetric concentration, local solid velocity, local solid mass flowrate and solid mass flowrate in gas-solid two-phase flow system is developed. It is based on a new type of a Capacitance-Electrostatic sensor (CES). The CES sensor is mainly composed of a capacitance electrode array and two electrostatic electrode arrays. The optimum design of the sensor is achieved by finite element method. The capacitance electrode array is employed to detect the solid distribution over the cross-section of the pipe, and the local solid volumetric concentration measurement is further derived. The electrostatic electrode arrays are used to measure the local solid velocities in conjunction with cross-correlation method. From the local solid velocity and local volumetric concentration, the solid mass flowrate and the local solid mass flowrate can be achieved. The developed system for the local solid volumetric concentration measurement is verified through analogue simulation experiments and static experiments. Finally, the system is employed to measure the local solid volumetric concentration, local solid velocity, local solid mass flowrate and solid mass flowrate on a belt conveyor. The experimental results show that the measurement error of the local solid volumetric concentration measurement results are less than 10.43% for solid local volumetric concentration ranging from 0.02 to 0.56, the standard deviations of the local solid velocity measurement results are less than 0.42 for solid velocity ranging from 3.5 m/s to 15.0 m/s, and the relative error of the solid mass flowrate is within ?19.6% to +14.9% for solid mass flowrate ranging from 0.006 kg/s to 0.103 kg/s, indicating that the system is capable of achieving multi-parameters measurement in gas-solid two-phase flow system.
Keywords:Instrumentation system  Capacitance-Electrostatic sensor  Local solid volumetric concentration  Local solid velocity  Local solid mass flowrate  Solid mass flowrate
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号