首页 | 本学科首页   官方微博 | 高级检索  
     

门站调压节流引起管道低温的分析
引用本文:张鸿鹏,李颜强.门站调压节流引起管道低温的分析[J].煤气与热力,2009,29(1):1-4.
作者姓名:张鸿鹏  李颜强
作者单位:中国市政工程华北设计研究院,天津,300074
摘    要:结合杭州市北门站高一中压调压器后管道低温结冰的运行实例,分析了调压节流后的低温燃气对管道系统的影响,提出了设计和校核的方法。

关 键 词:门站  调压站  节流效应

Analysis on Pipeline Low Temperature Caused by Pressure Regulation Throttling at Gate Station
ZHANG Hong-peng,LI Yan-qiang.Analysis on Pipeline Low Temperature Caused by Pressure Regulation Throttling at Gate Station[J].Gas & Heat,2009,29(1):1-4.
Authors:ZHANG Hong-peng  LI Yan-qiang
Affiliation:ZHANG Hong-peng, LI Yan-qiang
Abstract:Combined with the icing phenomenon of pipeline after the high-medium pressure regulator during the practical operation of Hangzhou North Gate Station, the influence of low temperature gas caused by pressure regulation throttling control on the pipeline system is analyzed, and the methods of design and check are put forward.
Keywords:gate station  regulator station  throttling effect