首页 | 本学科首页   官方微博 | 高级检索  
     

动叶可调轴流一次风机失速分析及预防措施
引用本文:周军,肖凌涛.动叶可调轴流一次风机失速分析及预防措施[J].发电设备,2008,22(6).
作者姓名:周军  肖凌涛
作者单位:妈湾发电总厂,广东,深圳,518052
摘    要:分析了妈湾发电总厂轴流一次风机失速情况,在DCS系统中采取失速预警、失速前预处理、失速判别及失速后设备联锁动作等措施,可以有效地减少由于热力系统缺陷导致风机失速的几率,同时可以减轻风机失速对机组运行的影响。

关 键 词:能源与动力工程  发电厂  轴流风机  性能曲线  失速  预警

Analysis on Stall of a Rotor Blade Adjustable Axial Flow Primary Air Fan and the Remedy
ZHOU Jun,XIAO Ling-tao.Analysis on Stall of a Rotor Blade Adjustable Axial Flow Primary Air Fan and the Remedy[J].Power Equipment,2008,22(6).
Authors:ZHOU Jun  XIAO Ling-tao
Abstract:By analyzing the stall failure of axial flow primary air fan in Mawan General Power Plant,it was found that the probability of stall caused by defects lying in the thermal system can be effectively reduced by taking countermeasures to the DCS system,such as pre-alarming of stall,pre-handling before stall,diagnosis of stall and interlocking action of relevant equipment after stall etc,these measures can simultaneously minimize the influence of air fan stall on operation of the power unit.
Keywords:energy and power engineering  power plant  axial flow fan  performance curve  stall  pre-alarming