摘    要:本文对电渗模型中电阻测量方法进行了改良,提出串联法代替当前的电势测针法和夹具法,并提出了适用于测量EKG电极电阻的走线法。串联不同长度的电渗土体测量电极与土体间的接触电阻消除了电势测针法中测针与电极之间一段土体电阻值的误差影响,同时避免了电势测针插入土壤对土壤电流分布的影响;串联不同长度的电渗电极测量电极电阻率时消除了夹具法测量时夹具和电极之间接触电阻的误差影响。经试验结果表明:电势测针法所得的接触电阻与串联法得到的接触电阻比值大多在1.3~1.4之间,验证了电势测针法将测针与电极间的一段土体值计入了接触电阻造成所测得的接触电阻偏大,该值的大小取决于该段土体电阻值;串联法对于当前应用广泛的EKG电极并不适用,提出了走线法来测量EKG电极电阻率消除电极板内因嵌入铜制导线电流分布不均的影响,走线法测量结果基本不受电极长度的影响,具有良好的可靠性和稳定性,走线法测量便捷,方便应用于EKG电极生产工艺中,有比较广阔的应用前景;走线法测量EKG电极所得的电阻率与夹具法得到电阻率的比值大多在8%~10%之间,该比值主要与夹具电极板间的接触电阻相关,夹具和电极板之间的接触电阻仅取决于夹具和电极板,故可利用该比值对先前使用夹具法的测量结果进行修正,在许多室内试验和工程中均用到了EKG电极,考虑EKG电极电阻率对整个试验和工程的能耗影响时可参考电阻率比值0.08~0.1进行修正。

关 键 词:电渗,电极电阻,接触电阻,EKG电极
收稿时间:2020/10/9 0:00:00
修稿时间:2021/4/27 0:00:00

Resistance Test Technology of Electroosmosis Model
ZHUANG Yanfeng,LIU Yani,GUO Kangshi.Resistance Test Technology of Electroosmosis Model[J].Journal of Sichuan University (Engineering Science Edition),2021,53(5):138-145.
Authors:ZHUANG Yanfeng  LIU Yani  GUO Kangshi
Affiliation:Wuhan University,
Abstract:The resistance measurement methods in the electroosmotic model was improved. The series method was proposed to replace the current electric potential measurement and fixture method, and the wiring method suitable for measuring the resistance of EKG electrode was proposed.The method of measuring contact resistance between electrode and soil with electroosmotic soil of different lengths in series eliminates the error influence of resistance of a section of soil between the measuring needle and electrode in electric potential measurement and avoids the influence on current distribution because of inserting the potentiometric needle in the soil. The method of measuring electrode resistivity with electrodes of different lengths in series eliminates the error influence of contact resistance between electrode and fixture in fixture method.The experimental results have shown that the ratio of contact resistance obtained by electric potential measurement to that obtained by series method was mostly between 1.3~1.4, which verified that the contact resistance measured by electric potential measurement is larger due to resistance of a section of soil between the needle and electrode is included in the contact resistance.The ratio depends on the resistance value of the soil between the needle and electrode.Series method for EKG electrode was not applicable.The wiring method was presented to measure EKG electrode resistivity to eliminate the influence of uneven current distribution in the electrode plate due to embedded copper wire. The measurement results of wiring method were basically not affected by the length of the electrode, with good reliability and stability. The wiring method was convenient and applied in EKG electrode in the production process.There is a broad application prospect.The ratio of resistivity of EKG electrode obtained by wiring method to that obtained by the fixture method was mostly between 8% ~ 10%. The ratio was mainly related to the contact resistance between electrode and fixture which just depended on the fixture and electrode. Therefore the ratio could be used to modify previous results obtained by fixture method. EKG electrodes have been used in many laboratory tests and projects. Considering the influence of the resistivity of EKG electrode on the energy consumption of the whole test and project, the resistivity ratio of 0.08~0.1 could be referred to for correction.
Keywords:electroosmosis  electrode resistance  contact resistance  EKG electrode