High-voltage surge protection by a varistor-filled air gap |
| |
Authors: | Pin Yang Carolina A Gomez Samantha Andrews Josef D Sorenson Ken S Chen |
| |
Affiliation: | Sandia National Laboratories, Albuquerque, NM, USA |
| |
Abstract: | The electric discharge across a varistor granule filled air gap under a fast-rising voltage pulse was investigated for surge protection applications. The effects of temperature and pressure on the arc and the electrical conduction were analyzed by the characteristic changes in voltage waveforms triggered by a fast-rising high voltage pulse. In addition to the gap size, experimental results show that competing mechanisms among arc conduction, conduction through the varistor granule network, thermionic emission from Joule heating at granule-to-granule contact points, and the magnitude of the switching voltage dictate the maximum surge protection voltage for the filled air gap. Experimental evidence indicated that accumulated degradation was created at small contact points between varistor granules by repetitive assaults from longer duration, high voltage pulses. The uniqueness of using varistor over other dielectric granules in an air gap for surge protection is identified and discussed. |
| |
Keywords: | arc flash breakdown gas discharge surge protection varistor |
|
|