摘    要:分析了锂离子电池组的电流采样误差较大的原因,并通过电压叠加电路的设计来解决充放电电流的区分问题。对电流采样值进行了分段插值方法校正,并对温度进行了直线校正。实验证明:校正后的电流值最大误差为0.02 A。

关 键 词:锂离子电池组  电量计量  电流采样
文章编号:1001-1579(2006)04-0291-02
修稿时间:2006年3月15日

Research on the current sampling precision in the electric quantity gauge
JIANG Xin-hua,FENG Yi,LEI Juan,XIE Jing-ying.Research on the current sampling precision in the electric quantity gauge[J].Battery Bimonthly,2006,36(4):291-292.
Authors:JIANG Xin-hua  FENG Yi  LEI Juan  XIE Jing-ying
Abstract:The reason of large errors in current sampling of Li-ion batteries was analyzed.The problem of distinguishing charge-discharge current was resolved by the voltage superposition circuit design.The value of current sampling was corrected by the subsection interpolation method,and temperature was corrected by the linear correction.The tests demonstrated that the maximum error of the corrected current value was 0.02 A.