Essential parameter calibration for the 3D scanner with only single camera and projector |
| |
Authors: | Li-mei Song Chang-man Chen Zhuo Chen Jiang-tao Xi and Yan-guang Yu |
| |
Affiliation: | 12395. Tianjin Key Laboratory of Advanced Technology of Electrical Engineering and Energy, Tianjin Polytechnic University, Tianjin, 300087, China 22395. School of Electrical, Computer and Telecommunications Engineering, University of Wollongong, Keiraville, 2500, Australia
|
| |
Abstract: | A calibration method for the five essential parameters is proposed. Using the calibration results, the three dimensional (3D) reconstruction can be performed directly. The five essential parameters include the distance between the camera and the projector, the distance between the reference plane and the camera, the fundamental frequency of the fringe pattern, the scale factor from the image coordinates to the world coordinate system in X axis direction and that in Y axis direction. The proposed calibration method is implemented and tested in our 3D reconstruction system. The mean calibration error is found to be 0.0215 mm over a volume of 400 mm (H)×300 mm (V)×500 mm (D). The proposed calibration method is accurate and useful for the 3D reconstruction system. |
| |
Keywords: | |
本文献已被 CNKI SpringerLink 等数据库收录! |
| 点击此处可从《光电子快报》浏览原始摘要信息 |
|
点击此处可从《光电子快报》下载全文 |
|