首页 | 本学科首页   官方微博 | 高级检索  
     

微波辅助萃取-超高效液相色谱-质谱法测定食品用纸容器中双酚A
引用本文:马晓斐,宋炜,梁天佐,贾振国,张岩. 微波辅助萃取-超高效液相色谱-质谱法测定食品用纸容器中双酚A[J]. 食品科学, 2014, 35(16): 165-169. DOI: 10.7506/spkx1002-6630-201416032
作者姓名:马晓斐  宋炜  梁天佐  贾振国  张岩
作者单位:1.河北省食品质量监督检验研究院,河北 石家庄 050091;2.河北省食品药品检验院,河北 石家庄 050011
基金项目:河北省质监局科技计划项目(2012ZD09)
摘    要:建立食品用纸容器中双酚A的超高效液相色谱-质谱检测方法。采用微波辅助萃取仪对样品进行萃取,Sep-Pak C18固相萃取柱净化,甲醇-水(含有体积分数0.05%氨水)作为流动相,梯度洗脱,经Kinetex C18(2.1 mm×100 mm,2.6 μm)色谱柱分离,采用电喷雾电离,多反应监测模式下进行测定。结果表明:该方法在
1.0~100.0 μg/L质量浓度范围内线性良好,其相关系数(r²)为0.999 7。在5、10 μg/kg和50 μg/kg 3 个添加水平下,双酚A的平均回收率稳定在90.5%~98.6%之间,相对标准偏差均小于5.6%,方法检出限2.5 μg/kg。该方法操作简便,灵敏度高,适用于食品用纸容器中双酚A残留分析。

关 键 词:超高效液相色谱-质谱  双酚A  微波辅助萃取  食品用纸容器  

Determination of Bisphenol A in Paper Food Containers by Ultra Performance Liquid Chromatography and Tandem Mass Spectrometry
MA Xiao-fei,SONG Wei,LIANG Tian-zuo,JIA Zhen-guo,ZHANG Yan. Determination of Bisphenol A in Paper Food Containers by Ultra Performance Liquid Chromatography and Tandem Mass Spectrometry[J]. Food Science, 2014, 35(16): 165-169. DOI: 10.7506/spkx1002-6630-201416032
Authors:MA Xiao-fei  SONG Wei  LIANG Tian-zuo  JIA Zhen-guo  ZHANG Yan
Affiliation:1. Hebei Institute of Food Quality Supervision Inspection and Research, Shijiazhuang 050091, China;2. Hebei Provincial Institute for Food and Drug Control, Shijiazhuang 050011, China
Abstract:A method for the determination of bisphenol A in paper food containers by ultra performance liquid
chromatography and tandem mass spectrometry (UPLC-MS-MS) after microwave-assisted extraction was developed.
Sample extracts were purification on a Sep-Pak C18 column. The target compound was separated on a Kinetex C18 (2.1 mm ×
100 mm, 2.6 μm) column using methanol-water (containing 0.05% ammonia water) as the mobile phase with gradient
elution, and detected by MS with electrospray ionization (ESI) under a multiple reaction-monitoring mode. In the range of
1.0 to 100.0 μg/L, the calibration curve developed showed good linearity with correlation coefficients (r²) of 0.999 7. The
recoveries for spiked samples were 90.5%–98.6% at three levels of 5, 10 and 50 μg/kg, and the relative standard deviations
were less than 5.6%. The limit of detection was 2.5 μg/kg. The method proved to be easy to use, timesaving, sensitive and
suitable for the determination of bisphenol A residues in food paper containers.
Keywords:ultra performance liquid chromatography tandem mass spectrometry  bisphenol A  microwave-assisted extraction  paper food containers  