摘    要:针对炼油厂6kV供电系统运行中多次发生电压互感器铁磁谐振,导致6 kV配电所电压互感器烧毁,避雷器爆炸,用电设备击穿,高压熔断器熔断,造成继电保护误动等问题进行了原因分析,提出了预防措施。

关 键 词:电压互感器  铁磁谐振  事故原因  预防措施

Problems and Precautionary Measures of Ferromagnetic Resonance of Voltage Mutual Inductors for 6 kV Power Supply System
Dong Changhai.Problems and Precautionary Measures of Ferromagnetic Resonance of Voltage Mutual Inductors for 6 kV Power Supply System[J].Metallurgical Power,1999(6):17-19.
Authors:Dong Changhai
Affiliation:Dong Changhai
Abstract:Ferromagnetic resonance of voltage mutual inductors for 6 kV power supply system of the oil refinery took place several times, resulting in burn- out of voltage mutual inductors of 6 kV substation, explosion of lightning guards, breakdown of electric equipment, fusing of high voltage fuses and misoperation of relaying protection. Reasons of the above problems are analyzed and precautionary measures are given.