Abstract: | The authors present an analysis of the causes of radiation induced complications in 383 patients referred to the Chair of Clinical Radiology from different medical institutions of the country. It was found that under distant gamma therapy, to prevent the development of complications the value of TDF-factor should not exceed 105--110, for the associated radiotherapy--130--140, and that for close focal roentgenotherapy--130--150. In vast majority of patients (95.3%) the complications resulted from surpassing the normal tissue tolerance. To prevent radiation injuries it is suggested to take into consideration the TDF-factor values, while in planning radiotherapy to choose such schedules of irradiation, which preclude any surpassing of the tolerance of normal tissues and organs adjacent to the tumor. |