首页 | 本学科首页   官方微博 | 高级检索  
     


EURAMET.T-K7 Key Comparison of Water Triple-Point Cells
Authors:A Peruzzi  R Bosma  O Kerkhof  P Rosenkranz  M D Del Campo Maldonado  R Strnad  J Nielsen  M Anagnostou  T Veliki  D Zvizdic  E Grudnewicz  M Nedea  D M Neagu  P Steur  E Filipe  I Lobo  I Antonsen  E Renaot  M Heinonen  T Weckstrom  J Bojkovski  E Turzo-Andras  S Nemeth  M White  E Tegeler  M Dobre  S Duris  A Kartal Dogan  A Uytun  V Augevicius  A Pauzha  A Pokhodun  S Simic
Affiliation:1. VSL, Dutch Metrology Institute, P.O. Box 654, 2600 AR, Delft, The Netherlands
2. BEV, Arltgasse 35, 1160, Wien, Austria
3. CEM, Alfar 2, 28760, Tres Cantos, Madrid, Spain
4. CMI, Okru?ni 31, 63800, Brno, Czech Republic
5. DTI, Kongsvang All?? 19, 8000, ?rhus, Denmark
6. EIM, Industrial Area of Thessaloniki, Block 45, 57022, Thessaloniki, Greece
7. FSB-LPM, Ivana Lu?i?a 5, 10002, Zagreb, Croatia
8. GUM, Ul. Elektoralna 2, 00950, Warsaw, Poland
9. INM, Sos Vitan-Barzesti 11, 042122, Bucharest, Romania
10. INRiM, Strada delle Cacce 91, 10135, Torino, Italy
11. IPQ, Rua Ant??nio Gi?o 2, 2829-513, Caparica, Portugal
12. JV, Fetveien 99, 2007, Kjeller, Norway
13. LNE-CNAM, Rue du Landy, 93210, La Plaine Saint Denis, Paris, France
14. MIKES, Tekniikantie 1, 02151, Espoo, Finland
15. MIRS/UL/FE-LMK, Tr?a?ka 25, 1000, Ljubljana, Slovenia
16. MKEH, N??metv?lgyi ??t 37-39, 1124, Budapest, Hungary
17. NSAI NML, Claremont Avenue, Glasnevin, Dublin 9, Ireland
18. PTB, Abbestrasse 2-12, 10587, Berlin, Germany
19. SMD, Boulevard du Roi Albert II 16, 1000, Brussels, Belgium
20. SMU, Karlovesk?? 63, 84255, Bratislava, Slovakia
21. UME, Anibal Cad. Be?evler, 41470, Gebze, Kocaeli, Turkey
22. VMT/PFI, Gostauto str. 11, 2600, Vilnius, Lithuania
23. VNIIM, Moskovsky pr. 19, 190005, St. Petersburg, Russia
24. ZMDM, Mike Alasa 14, 11000, Beograd, Serbia
Abstract:The results of a EURAMET key comparison of water triple-point cells (EURAMET.T-K7) are reported. The equipment used, the measuring conditions applied, and the procedures adopted for the water triple-point measurement at the participating laboratories are synthetically presented. The definitions of the national reference for the water triple-point temperature adopted by each laboratory are disclosed. The multiplicity of degrees of equivalence arising for the linking laboratories with respect to the ??mother?? comparison CCT-K7 is discussed in detail.
Keywords:
本文献已被 SpringerLink 等数据库收录!