首页 | 本学科首页   官方微博 | 高级检索  
     


Micromachined ultrasonic capacitance transducers for immersion applications
Authors:Bashford A G  Schindel D W  Hutchins D A
Affiliation:Dept. of Eng., Warwick Univ., Coventry.
Abstract:
Investigations into the characteristics of water-coupled ultrasonic capacitance transducers have been undertaken for a range of transducer configurations. The radiated fields have been scanned in water using a miniature hydrophone detector, and the results compared to theory based on a plane piston approach. Micromachined backplates in conjunction with thin Mylar and mica membranes have been investigated, together with aperture modifications such as an annulus and Fresnel zone plate. The measured results agree well with theory, thus demonstrating that wideband predictable performance (>8 MHz) is obtainable with such transducers. Additionally, pulse-echo C-scans of a Plexiglas plate containing an artificial defect have been undertaken with the capacitance transducer, in order to demonstrate that the capacitance transducer has sufficient sensitivity to allow routine nondestructive testing within immersion applications.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏