Transient analysis of heat pump assisted distillation systems. 1 The heat pump
Authors:M. A. Salim  M. Sadasivam  A. R. Balakrishnan
Abstract:
A simple algorithm to simulate the transient behaviour of a vapour compression heat pump is described. Individual models are developed for various components of the heat pump such as compressor, evaporator, condenser and expansion valve. The components are simulated separately and are combined to form the total system. The compressor is a hermetically sealed, reciprocating piston type with adiabatic compression, the evaporator and condenser are coiled copper tubes, and the expansion valve is assumed to be adiabatic. The transport and thermodynamic properties of the refrigerant used are obtained from empirical equations. The total system is viewed in a simplified manner in order to apply the results of this transient analysis to the behaviour of a chemical process operation, namely, distillation.
Keywords:Heat pump  Heat pump assisted distillation  Transient analysis  Simulation