首页 | 本学科首页   官方微博 | 高级检索  
     


Comments on “Viscoelastic studies of human subscapularis tendon: Relaxation test and a Wiechert model” by C. Machiraju, A.V. Phan, A.W. Pearsall, S. Madanagopal, Computer Methods and Programs in Biomedicine (2006)
Authors:Z.W. Wang  C.Y. Tang
Affiliation:aDepartment of Process Equipment and Control Engineering, Dalian University of Technology, Dalian 116012, PR China;bDepartment of Industrial and Systems Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong, PR China
Abstract:Referring to the approach for determining the material parameters for a Wiechert model of the human subscapularis tendon proposed by Machiraju et al. [C. Machiraju, A.V. Phan, A.W. Pearsall, S. Madanagopal, Viscoelastic studies of a human subscapularis tendon: relaxation test and a Wiechert model, Computer Methods and Programs in Biomedicine (2006), doi:10.1016/j.cmpb.2006.05.004], some comments are made on the basis of the result of an alternative method that is capable of giving more reasonable values for the Wiechart model with the fitting discrepancies minimized by a multi-variable optimization strategy.
Keywords:Tendon   Viscoelastic   Wiechert model   Stress relaxation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号