Increasing the reliability and service life of the cathode unit of an electron accelerator with extraction of a large-cross-section beam to the atmosphere |
| |
Authors: | T E Anisimova A N Malinin |
| |
Affiliation: | (1) Research Institute of Complex Testing of Optoelectronic Devices, Sosnovyi Bor, Leningrad oblast, 188540, Russia |
| |
Abstract: | The design of an electron accelerator cathode unit with short filament elements in the form of a coil without a tightening mechanism is described. The advantage of the developed design over those of cathodes with long filaments with tightening mechanisms is shown. The nonuniformity of the beam-current density distribution behind the foil is <3%. The filament power required for cathodes in the form of coils is 20% lower than that for long-filament cathodes at the same beam-current density. Mechanical stresses leading to a breakdown of the cathode filaments are absent. The service life is determined mainly by the emission-caused wear of cathodes. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |