首页 | 本学科首页   官方微博 | 高级检索  
     


Renal expression of a transforming growth factor-alpha transgene accelerates the progression of inherited, slowly progressive polycystic kidney disease in the mouse
Authors:VH Gattone  KA Kuenstler  GW Lindemann  X Lu  BD Cowley  CA Rankin  JP Calvet
Affiliation:Department of Pathology, Free University, Amsterdam, The Netherlands.
Abstract:DNA ploidy measurement by flow (FCM) or image cytometry (ICM) of single cell suspensions of solid tumour has prognostic value, but it would be a definite advantage if the assessment could be done on histological sections. However, this is usually not possible by means of standard ICM, due to the capping of nuclei in thin sections, or overlap in thick sections. Three-dimensional (3D) microscopy by means of confocal laser scanning microscopy (CLSM) could solve this problem in theory but the results published so far are not very satisfactory. A new method has been developed in which the DNA content of haploid (human testis spermatozoa), diploid, tetraploid, octaploid (human and rat liver and human spermatogonia), and near-triploid (human breast cancer) nuclei stained with YOYO-1 iodide has been measured by a newly developed 3D image cytometry method (3DICM) in 20 microns thick histological sections. YOYO-1 iodide is a new highly sensitive, specific, stoichiometric, and stable fluorescent dye for DNA. DNA ploidy of a breast cancer which was near-triploid with FCM and ICM was also assessed with 3DICM in a tissue section adjacent to the section used for FCM and ICM and the results were compared. The integrated 3DICM fluorescence intensity showed good linearity (r = 0.99) with the real DNA content of all nuclei analysed. In human tissue, the coefficient of variation of 3DICM for haploid (n = 12), diploid (n = 63), triploid (n = 13), tetraploid (n = 12), and octaploid (n = 3) ploidy distributions was 5.1, 6.6, 4.2, 4.0, and 0.6 per cent, respectively (n = the number of nuclei). For the rat liver, the CV of the diploid (n = 21), tetraploid (n = 31), and octaploid (n = 3) peaks was 6.7, 4.8, and 1.6 per cent, respectively. Repeated "blind' measurements of nuclei with different DNA indices showed excellent reproducibility between different observers (r = 0.98). It is concluded that the 3DICM method used is accurate, reproducible, and clinically feasible in thick histological sections. This is especially important in small lesions, or if the results of DNA ploidy measurement of single cell suspensions (by FCM) or imprints (by ICM) are inadequate.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号