Experimental investigation of particle distribution in a flow through a stenosed artery |
| |
Authors: | Anis Shuib Peter Hoskins William Easson |
| |
Affiliation: | (1) Department of Mechanical Engineering, Pohang University of Science and Technology, San 31, Hyoja-Dong, Nam-Gu, Pohang, Kyungbuk, 790-784, Korea |
| |
Abstract: | ![]() The particle distribution of a dilute solid-liquid suspension through a stenosed arterial geometry was investigated. Particle image velocimetry (PIV) was used to determine the velocity as well as to acquire the flow images. The light intensity scattered by particles was evaluated to determine the particle distribution. Flow separation exists where the flow emerges from the stenosis throat. From the PIV images, the particle density distribution exhibited differing non-uniform characteristics which vary with flow rate, particle size and particle concentration. At low flow rates, a particle-free layer is formed. As the flow rate is increased, particles accumulate in concentric recirculation orbits within the downstream vortex. Particles with larger size and higher concentration tend to accumulate more towards the center of the vortex. |
| |