首页 | 本学科首页   官方微博 | 高级检索  
     


Li+ alumino-silicate ion source development for the neutralized drift compression experiment
Authors:Roy Prabir K  Greenway Wayne G  Kwan Joe W  Seidl Peter A  Waldron William L  Wu James K
Affiliation:Lawrence Berkeley National Laboratory, California 94720, USA. PKRoy@lbl.gov
Abstract:We report results on lithium alumino-silicate ion source development in preparation for warm dense matter heating experiments on the new neutralized drift compression experiment II. The practical limit to the current density for a lithium alumino-silicate source is determined by the maximum operating temperature that the ion source can withstand before running into problems of heat transfer, melting of the alumino-silicate material, and emission lifetime. Using small prototype emitters, at a temperature of ≈1275 °C, a space-charge limited Li(+) beam current density of J ≈1 mA/cm(2) was obtained. The lifetime of the ion source was ≈50 h while pulsing at a rate of 0.033 Hz with a pulse duration of 5-6 μs.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号