轴瓦温度跳变的原因分析及处理
引用本文:李春明.轴瓦温度跳变的原因分析及处理[J].贵州电力技术,2011(1):49-51.
作者姓名:李春明
作者单位:贵州黔源北盘江光照发电厂,贵州晴隆561405
摘    要:机组轴承的测温电阻质量参差不齐,测温电阻电缆长期浸泡在导轴承、推力轴承油槽里,使电缆外皮变硬变脆。电缆长期受高温油流的冲击,造成运行中测温电阻电缆断裂。机组长时间运行在振动区,造成测温回路端子松动。

关 键 词:发电厂  测温电阻  分析原因  应对措施

Reasons analysis and treatment on the hopping of unit bearing temperature
Li Chunming.Reasons analysis and treatment on the hopping of unit bearing temperature[J].Guizhou Electric Power Technology,2011(1):49-51.
Authors:Li Chunming
Affiliation:Li Chunming ( Guangzhao Electric Power Plant, Qinglong 561405 Guizhou, China)
Abstract:The difference in quality and used in thrust bearing groove and journal bearing groove for a long time results temperature resistance' s sheath stiff and brittle. The impact of high temperature oil flow for a long time causes the cable of running temperature resist- ance broken. The long time running in vibration area of units causes temperature loop terminal flexible.