摘    要:通过对张家口地区过网电量的分析,讨论了影响110 kV及以上电网线损的几个因素,从而提出降损措施,并对未来风电大量投运对线损的影响进行讨论。

关 键 词:线损  过网电量  电网结构  运行方式
文章编号:1003-9171(2006)06-0020-03
收稿时间:2006-03-02
修稿时间:2006-03-02

Factors of Influencing 110 kV and Over Network Line Losses in Zhangjiakou Area
Qiu Jing,Wu Yu-ping.Factors of Influencing 110 kV and Over Network Line Losses in Zhangjiakou Area[J].North China Electric Power,2006(6):20-22,42.
Authors:Qiu Jing  Wu Yu-ping
Affiliation:Zhangjiakou Power Supply Co. Dispatching Institute, Zhangjiakou 075000,China
Abstract:On the basis of analyzing the through quatity of electricity in Zhangjiakou electric power Network,this paper discusses the factors of influencing 110 kV and over network Line losses,puts foward the methocl of reducing Line Losses,and discusses the influence of wind power generation placing in quantity in service to Line Losses.
Keywords:Line Losses  through quatity of electricity in power network  grid structure  operative mode