首页 | 本学科首页   官方微博 | 高级检索  
     


An acute clinical comparison of corneal staining and comfort associated with contact lens care solutions
Affiliation:1. Department of Ophthalmology, Baylor College of Medicine, Houston, Texas;2. Department of Ophthalmology and Visual Science, University of Texas Health Science Center, Houston, Texas;1. Université de Montréal, École d’optométrie, 3744 Jean-Brillant, Suite 190-70 Montréal, Canada,;2. Université de Montréal, École d’optométrie, 3744 Jean-Brillant, Suite 190-66 Montréal, Canada
Abstract:PurposeThis study compared the biocompatibility and comfort of 4 lens care solutions currently marketed in France.MethodsThis was a randomized, interventional, double-masked, single-center crossover study assessing balafilcon A silicone hydrogel contact lenses, bilaterally, straight from the blister pack solution (control) and pre-soaked in the following lens care solutions: Regard® (containing sodium chlorite), ReNu® (containing a PHMB polyhexamethylene biguanide] derivative), CyClean? and MeniCare? Soft (both containing PHMB). Subjects were randomized to the order of test solution use. For each of the 5 solutions tested, subjects attended a baseline/lens dispensing visit and an intervention visit 2 h later. At both visits, evaluation included slit-lamp examination, corrected-distance visual acuity, corneal staining, and subject-assessed photophobia, ocular comfort, and ocular redness.ResultsThirty subjects were enrolled and 28 were evaluable. Corneal staining severity was significantly worse than baseline after 2 h of wearing lenses soaked in CyClean, MeniCare, or ReNu (P  0.001). The MeniCare group alone demonstrated a significant improvement in ocular comfort after 2 h of lens wear (P = 0.02). No group demonstrated significant changes in ocular redness or photophobia. Corrected-distance visual acuity was similar between baseline and intervention visits for each test solution. No adverse events were reported during the study.ConclusionsSilicone hydrogel contact lenses presoaked in lens solutions containing PHMB or a PHMB derivative produced an increase in corneal staining after 2 h of lens wear. The higher levels of corneal staining in the 2 solutions did not correlate with increased discomfort within this 2-h timeframe.
Keywords:Contact lens care solution  Corneal staining  Fluorescein  Polyhexamethylene biguanide  Solution-induced corneal staining
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号