压头面积函数对纳米压入测试结果的影响
引用本文:郭振丹,王秀芳,杨晓萍,马学鸣,蒋冬梅,宋洪伟. 压头面积函数对纳米压入测试结果的影响[J]. 理化检验(物理分册), 2008, 44(3): 111-115
作者姓名:郭振丹  王秀芳  杨晓萍  马学鸣  蒋冬梅  宋洪伟
作者单位:华东师范大学,物理系,上海,200062;宝山钢铁股份有限公司,技术中心,上海,201900;宝山钢铁股份有限公司,技术中心,上海,201900;华东师范大学,物理系,上海,200062
摘    要:
从纳米压入测量的基本原理出发介绍了压头面积函数及其校对方法,并对熔融石英进行了两次纳米压入测量,校对了两次压头面积函数,两次测量及校对的时间间隔为1a(年)。结果表明,两次校对后的压头面积函数差别较大。若第二次测量的熔融石英数据仍采用第一次校对的面积函数进行计算,将使杨氏模量和硬度测量结果产生很大误差,阐明了压头面积函数校对在纳米压入测试中的重要作用。

关 键 词:纳米压入  压头面积函数  杨氏模量  硬度
文章编号:1001-4012(2008)03-0111-04
修稿时间:2007-04-05

EFFECT OF TIP AREA FUNCTION ON NANOINDENTATION RESULTS
GUO Zhen-dan,WANG Xiu-fang,YANG Xiao-ping,MA Xue-ming,JIANG Dong-mei,SONG Hong-wei. EFFECT OF TIP AREA FUNCTION ON NANOINDENTATION RESULTS[J]. Physical Testing and Chemical Analysis Part A:Physical Testing, 2008, 44(3): 111-115
Authors:GUO Zhen-dan  WANG Xiu-fang  YANG Xiao-ping  MA Xue-ming  JIANG Dong-mei  SONG Hong-wei
Affiliation:GUO Zhen-dan, WANG Xiu-fang, JIANG Dong-mei, YANG Xiao-ping, MA Xue-ming, SONG Hong-wei(1. Department of Physics, East China Normal University, Shanghai 200062, China; 2. Baosteel Technology Center, Baoshan Iron & Steel Co. Ltd. , Shanghai 201900, China)
Abstract:
The tip area function and its calibration method were introduced based on the basic principles of nanoindentation. A nanoindentation test on a fused silica and the calibration of the tip area function were pel-formed in sequence, The test and calibration were repeated one year later. It was found that two tip area functions got from calibrations varied significantly. Calculating the data collected from the fused silica one year later by using the tip area function got from the first calibration leaded to big differences between results of Young's modulus and that of hardness. The calibration of tip area function played an important role in nanoindentation test.
Keywords:Nanoindentation  Tip area function  Young's modulus  Hardness