首页 | 本学科首页   官方微博 | 高级检索  
     


Shear tests on full scale storey‐height specimens constructed with thermally insulating clay unit masonry with thin‐layer mortar
Authors:Prof Dr‐Ing Detleff Schermer  Dr‐Ing Udo Joachim Meyer  Marjana Lutman  Petra Triller
Affiliation:1. Ostbayerische Technische Hochschule Regensburg, Fakult?t Bauingenieurwesen, Prüfeninger Str. 52, D‐93049 Regensburg;2. Arbeitsgemeinschaft Mauerziegel im Bundesverband der Deutschen Ziegelindustrie e. V., Reinhardtstra?e 12‐16, D‐10117 BerlinCorrespondence: Dr.‐Ing. Udo Joachim Meyer, Arbeitsgemeinschaft Mauerziegel im Bundesverband der Deutschen Ziegelindustrie e. V., Reinhardtstra?e 12‐16, D‐10117 Berlin;3. Dimi?eva ulica 12, Slovenia, 1000 Ljubljana
Abstract:The paper presents results of a series of 6 in‐plane shear tests on storey‐height clay unit masonry panels 1] with thin‐layer mortar, carried out in addition to previous test campaigns 2], 3], and 4]. The walls were constructed with unfilled thermally insulating clay units with a thermal conductivity of λ = 0.09 W/(m · K). The current design rules for clay unit masonry according to DIN EN 1996‐1‐1/NA 5] are conservative compared to the presented test results for thermally insulating clay unit masonry.
Keywords:clay units  thin‐layer mortar  in‐plane shear  design  test methods  Ziegel  Mauerwerk mit Dü  nnbettmö  rtel  Schub  Bemessung  experimentelles Prü  fverfahren    nnbettmö  rtel  building materials/building products  analysis/design  testing methods  Baustoffe/Bauprodukte  Berechnung/Bemessung  Prü  fverfahren
设为首页 | 免责声明 | 关于勤云 | 加入收藏