首页 | 本学科首页   官方微博 | 高级检索  
     

山铝热电厂01#循环流化床锅炉膜式省煤器改造
引用本文:陆志军,王晶. 山铝热电厂01#循环流化床锅炉膜式省煤器改造[J]. 锅炉制造, 2006, 0(3): 31-32
作者姓名:陆志军  王晶
作者单位:1. 山东铝业股份有限公司热电厂,山东,淄博,255052
2. 中铝山东分公司设计院,山东,淄博,255052
摘    要:山东铝业股份有限公司热电厂01#循环流化床锅炉省煤器自投产以来频繁出现爆管故障,通过对历次故障情况进行综合分析,提出了减少省煤器管排数、改善防磨结构、降低烟气流速减轻磨损的膜式省煤器改造方案,改造实施后运行效果良好。

关 键 词:流化床锅炉 磨损 膜式省煤器 改造
文章编号:CN23-1249(2006)03-0031-02
收稿时间:2006-04-13
修稿时间:2006-04-13

Renovation of Membrane Economizer of CFB in Shandong Aluminum Company Heat and Power Plant 01#
Lu Zhijun,Wang Jing. Renovation of Membrane Economizer of CFB in Shandong Aluminum Company Heat and Power Plant 01#[J]. Boiler Manufacturing, 2006, 0(3): 31-32
Authors:Lu Zhijun  Wang Jing
Abstract:Tube Rupture happened frequently since CFB in Shandong Aluminum Company Heat and Power Plant 01 # put into product, through analysis of accident condition,renovation measures were taken, such as reducing economizer tube number, improving anti - wear structure, slowing flue gas rate to improve operation status.
Keywords:CFB   wear   membrane economizer   renovation
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号