东莞市星级酒店空调用能现状与节能分析
引用本文:张金明,冀兆良,邱平. 东莞市星级酒店空调用能现状与节能分析[J]. 制冷空调与电力机械, 2011, 32(1): 66-69
作者姓名:张金明  冀兆良  邱平
作者单位:广州大学土木工程学院,广东,广州,510006
摘    要:对东莞市5栋酒店建筑单位面积能耗、空调冷热源方式、空调能耗、热环境参数、人员舒适性进行了实测,并进行了能耗分析。结果表明:单位建筑面积建筑能耗平均值为2.273GJ/(m2.a)单位空调面积空调能耗平均值为1.181 GJ/(m2.a)。根据测试及计算结果指出了该市酒店建筑空调系统存在的问题,并对其节能进行了分析。

关 键 词:建筑能耗  空调能耗  节能  热舒适

Analysis of Energy Consumption and Energy Saving for Air-conditioning in Star Hotels in Dongguan
MANG Jin-ming,JI Zhao-liang,QIU Ping. Analysis of Energy Consumption and Energy Saving for Air-conditioning in Star Hotels in Dongguan[J]. Refrigeration Air Conditioning & Electric Power Machinery, 2011, 32(1): 66-69
Authors:MANG Jin-ming  JI Zhao-liang  QIU Ping
Affiliation:ZHANG Jin-ming,JI Zhao-liang,QIU Ping(Civil Engineering College,Guangzhou University,Guangzhou 510006,China)
Abstract:Measured energy consumption of per building area,cold and heat sources,energy consumption of air conditioning and thermal environment parameters,then analyzed the energy consumption.The results showed that the average of building energy consumption was 2.273GJ/(m2·a)and the average of energy consumption of air conditioning was 1.181GJ/(m2·a).According to the test and calculation,pointed out some existing problems of air-conditioning system in hotels in Dongguan,and analyzed the energy saving.
Keywords:building energy consumption  energy consumption of air-conditioning  energy saving  thermal comfort  