首页 | 本学科首页   官方微博 | 高级检索  
     

1025t/h强制循环锅炉燃烧调整试验
引用本文:夏明松,朱全利,乐晓萍,林逸平. 1025t/h强制循环锅炉燃烧调整试验[J]. 华中电力, 2003, 16(2): 19-21
作者姓名:夏明松  朱全利  乐晓萍  林逸平
作者单位:1. 武汉大学,湖北,武汉,430072
2. 丰城发电厂,江西,丰城,331100
摘    要:对丰城电厂1025t/h强制循环炉进行了燃烧调整试验及N0x排放量的试验,分析了影响该炉燃烧特性的主要因素,并提出合理的运行方式,为该炉高效低N0x运行提供了依据。

关 键 词:1025t/h强制循环锅炉 燃烧调整 试验 燃烧特性 燃烧器
文章编号:1006-6519(2003)02-0019-03

Test on the Combustion Performance of a 1025t/h Forced Circulation Boiler
XIA Ming-song ,ZHU Quan-li ,LE Xiao-ping ,LIN Yi-ping. Test on the Combustion Performance of a 1025t/h Forced Circulation Boiler[J]. Central China Electric Power, 2003, 16(2): 19-21
Authors:XIA Ming-song   ZHU Quan-li   LE Xiao-ping   LIN Yi-ping
Affiliation:XIA Ming-song 1,ZHU Quan-li 1,LE Xiao-ping 2,LIN Yi-ping 2
Abstract:The combustion performance and NO X emissions of a1025t/h forced circulation boiler by the experi-ments were studied in this paper.The major influence factors of the combustion wer e analyzed and the reasonable run man ner of boiler was put forward,which can keep the boiler in high efficiency and low-NO X run.
Keywords:boiler  WR burner  combustion test
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号