首页 | 本学科首页   官方微博 | 高级检索  
     

聊城热电厂7号机组异常振动分析处理
引用本文:许怀志,王红. 聊城热电厂7号机组异常振动分析处理[J]. 山东电力技术, 2007, 0(4): 32-33
作者姓名:许怀志  王红
作者单位:山东电力研究院 山东济南250002(许怀志),重汽一中 山东济南250031(王红)
摘    要:
介绍了聊城热电厂7号机组的振动问题,分析了机组振动的主要原因,精确分析出不平衡重量存在的部位,通过加重处理成功消除了机组的振动故障,振动达到优良水平,保证了机组的安全投产运行。

关 键 词:现场平衡  振动  处理

Analysis and Treatment of Abnormal Vibration of Unit 7 in Liaocheng Thermal Power Plant
Xu Huaizhi et al. Analysis and Treatment of Abnormal Vibration of Unit 7 in Liaocheng Thermal Power Plant[J]. Shandong Electric Power, 2007, 0(4): 32-33
Authors:Xu Huaizhi et al
Affiliation:Xu Huaizhi et al
Abstract:
This paper discussed the vibration problem of Unit 7 in Liaocheng Thermal Power Plant. The main vibration reasons for Unit were analyzed, and the position of unbalance weight was accurately analyzed. Then successfully handled through field balance to eliminate the vibration fault for level of excellence . Guaranteed the safety of the unit during operation .
Keywords:field balance  vibration  treatment
本文献已被 CNKI 维普 等数据库收录!