摘    要:介绍装配式建筑的优势及相关政策。分析控制地面辐射供暖系统的管线分离比例对提高装配率的重要性。传统地面辐射供暖系统由于埋地盘管长度很大,导致管线分离比例过低,提出采取干式工法地面辐射供暖系统(架空地面辐射供暖系统、预制沟槽地面辐射供暖系统)予以解决。介绍两种干式工法地面辐射供暖系统的结构、造价及特点。以木地板、瓷砖分别作为饰面层,对预制沟槽地面辐射供暖系统进行散热量测试,当辐射面积一定时,以瓷砖作为饰面层的预制沟槽地面辐射供暖系统供暖能力强。分析装配式建筑中暖通专业的设计要点。

关 键 词:装配式建筑  管线分离比例  干式工法地面辐射供暖系统  设计要点

Design of Floor Radiant Heating System for Prefabricated Building
HAO Qi,MA Kunru.Design of Floor Radiant Heating System for Prefabricated Building[J].Gas & Heat,2021,41(1):28-31,10043.
Authors:HAO Qi  MA Kunru
Abstract:The advantages and related policies of prefabricated building are introduced. The importance of controlling the separation ratio of pipelines in the floor radiant heating system to improve the assembly rate is analyzed. Due to the large length of the buried coil in the traditional ground radiant heating system,the pipeline separation ratio is too low. It is proposed to adopt non-wet construction floor radiant heating system( overhead floor radiant heating system and pre-groove floor radiant heating system) to solve this problem. The structure,cost and characteristics of two dry construction ground radiation heating system are introduced. Using wood floors and ceramic tiles as decorative layers,the bulk test of the pre-groove floor radiant heating system was conducted. When the radiation area is fixed,the heating capacity of the pregrooved floor radiant heating system with ceramic tiles as the decorative layer is strong. The design points of HVAC professional in prefabricated buildings are analyzed.
Keywords:prefabricated building  pipeline separation ratio  non-wet construction floor radiation heating system  design point